Eaton DG1 Variable frequency drive
Article No.:
9702-5006-00P
Part No.:
DG1-34140FB-C21C
Brand:

Variable frequency drive, 400 V AC, 3-phase, 140 A, 75 kW, IP21/NEMA1, Brake chopper, DC link choke
Availability:
Forward delivery 6-9 weeks
Part No. | DG1-34140FB-C21C |
---|---|
UOM | EA |
Weight (KG) | 75.90 |
---|
Description
Variable frequency drive, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Rated operational current At 150% overload: Ie = 140 A, Note: Rated operational current for a switching frequency of 1 - 10 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload, Rated operational current At 110% overload: Ie = 170 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 75 kW, 110 % Overload: P = 90 kW, 150 % Overload: IM = 134 A, 110 % Overload: IM = 161 A, Assigned motor rating Note: at 500 V, 50 Hz, Assigned motor rating 150 % Overload: P = 90 kW, 110 % Overload: P = 110 kW, 150 % Overload: IM = 129 A, 110 % Overload: IM = 157 A, Assigned motor rating Note: at 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 100 HP, 110 % Overload: P = 125 HP, Assigned motor rating 150 % Overload: IM = 124 A, 110 % Overload: IM = 156 A, Degree of Protection: IP21/NEMA1, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, Brake chopper, DC link choke, Frame size: FS5, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5
Resources / Data Sheets
Related Products
-
Part No.: DA1-354D1NB-B6SCEaton DA1 Variable frequency driveUOM: EAAvailability:Forward delivery 6-9 weeksPart No.: PKZM0-10-SC/AKEaton Moeller® series PKZM0 Motor-protective circuit-breakerUOM: EAAvailability:Forward delivery 6-9 weeksPart No.: DA1-34030FB-B20CEaton DA1 Variable frequency driveUOM: EAAvailability:Forward delivery 6-9 weeksPart No.: OPTC2Field bus module Modbus RS485 with screw terminals for variable frequency drive SVX and SPX (OPTC2 | Eaton SVX/SPX modbus RTU communication coard | Specifications | Eaton). OPTC2UOM: EAAvailability:Forward delivery 6-9 weeksPart No.: DA1-35130NB-B55CEaton DA1 Variable frequency driveUOM: EAAvailability:Forward delivery 6-9 weeksPart No.: S811+N66N3SEaton S811 Soft starter combinationUOM: EAAvailability:Forward delivery 6-9 weeksPart No.: PKZM0-6,3/AKEaton Moeller® series PKZM0 Motor-protective circuit-breakerUOM: EAAvailability:Forward delivery 6-9 weeksPart No.: PKZM0-2,5-GVP2Eaton Moeller® series PKZM0 Motor-protective circuit-breakerUOM: EAAvailability:Forward delivery 6-9 weeksPart No.: PKZM0-0,4-GVP2Eaton Moeller® series PKZM0 Motor-protective circuit-breakerUOM: EAAvailability:Forward delivery 6-9 weeksPart No.: DG1-34310FN-C00CVFD DG1 460V FR7 IP00 160KW 250HP AMRUOM: EAAvailability:Forward delivery 6-9 weeks